Ce-niehoff-co N1335 Troubleshooting Guides User Manual

Browse online or download User Manual for Hardware Ce-niehoff-co N1335 Troubleshooting Guides. C.E. Niehoff & Co. N1335 Troubleshooting Guides User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 6
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Page 1
TG0052A
Indicates presence of hazards that
will or can cause minor personal
injury or property damage if
ignored.
Indicates special instructions on
installation, operation or mainte-
nance that are important but not
related to personal injury hazards.
Table of Contents
Section 1: Wiring .......................................................... 2
Section 2: CAN/J1939 Diagnostics ............................... 3
Section 3: Basic Troubleshooting ................................. 4
Section 4: Advanced Troubleshooting ..................... 5 - 6
Battery Conditions
Until temperatures of electrical
system components stabilize, these
conditions may be observed during
cold start voltage tests.
Maintenance/Low Maintenance Battery:
Immediately after engine starts, system volts
measure lower than regulator setpoint and
system amps measure at a medium level.
3-5 minutes into charge cycle, volts increase and
amps decrease.
5-10 minutes into charge cycle, volts reach
regulator setpoint or very close, and amps
decrease to a minimum.
Low maintenance battery has same characteris-
tics with slightly longer recharge times.
Maintenance-free Battery:
Immediately after engine starts, system volts
measure lower than regulator setpoint with low
charging amps.
Once the charge cycle begins, low volts and low
amps are still present.
After the alternator energizes, voltage will
increase several tenths. Amps will increase
gradually, then quickly, to medium to high amps.
Finally, volts will increase to setpoint and amps
will decrease.
The time it takes to reach optimum voltage and am-
perage will vary with engine speed, load, and ambient
temperature.
High-cycle Maintenance-free Battery:
These batteries respond better than standard
maintenance-free. Charge acceptance of these
batteries may display characteristics similar to
maintenance batteries.
NOTICE
Hazard De nitions
These terms are used to bring attention to presence of hazards
of various risk levels or to important information concerning
product life.
NOTICE
N1335 Alternator
Troubleshooting Guide
Charge Volt and Amp Values
Volt and amp levels fluctuate depending on the battery
state of charge. If batteries are in a state of discharge
as after extended cranking time to start the engine—
system volts will measure lower than the regulator set-
point after the engine is restarted and system amps will
measure higher. This is a normal condition for the
charging system; the greater the battery discharge level,
the lower the system volts and the higher the system
amps. The volt and amp readings will change as batter-
ies recover and become fully charged: system volts will
increase to regulator setpoint and system amps will
decrease to low level (depending on other loads).
Low Amps: Minimum or lowest charging system
amp value required to maintain battery state of
charge, obtained when testing the charging system
with a fully charged battery and no other loads
applied. This value will vary with battery type.
Medium Amps: System amps value which can cause
the battery temperature to rise above adequate
charging temperature within 4-8 hours of charge
time. To prevent battery damage, the charge amps
should be reduced when battery temperature rises.
Check battery manufacturer’s recommendations for
proper charge amp rates.
High Amps: System amps value which can cause
the battery temperature to rise above adequate
charging temperature within 2-3 hours of charge
time. To prevent battery damage, the charge amps
should be reduced when battery temperature rises.
Check battery manufacturer’s recommendations for
proper charge amp rates.
Battery Voltage: Steady-state voltage value as mea-
sured with battery in open circuit with no battery
load. This value relates to battery state of charge.
Charge Voltage: Voltage value obtained when the
charging system is operating. This value will be
higher than battery voltage and must never exceed
the regulator voltage setpoint.
B+ Voltage: Voltage value obtained when measuring
voltage at battery positive terminal or alternator B+
terminal.
Surface Charge: Higher than normal battery voltage
occurring when the battery is disconnected from
battery charger. The surface charge must be removed
to determine true battery voltage and state of charge.
Significant Magnetism: Change in strength or
intensity of a magnetic field present in alternator
rotor shaft when the field coil is energized. The
magnetic field strength when the field coil is ener-
gized should feel stronger than when the field is not
energized.
Voltage Droop or Sag: Normal condition occurring
when the load demand on alternator is greater than
rated alternator output at given rotor shaft RPM.
CAUTION
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - Troubleshooting Guide

Page 1TG0052A Indicates presence of hazards that will or can cause minor personal injury or property damage if ignored. Indicates special ins

Page 2 - Section 1: Wiring Diagram

Page 2TG0052ASection 1: Wiring DiagramCEN N1335 Alternators Description and OperationN1335 28 V 300 A alternators are internally rectified. All windi

Page 3 - CAN/J1939 Interface

Page 3TG0052ASection 2: CAN/J1939 DiagnosticsCAN/J1939 InterfaceDESCRIPTION AND OPERATIONThe CEN N3234 digital regulator is compatible with SAE J193

Page 4

Page 4TG0052ASection 3: Basic TroubleshootingD. Basic Troubleshooting1. Inspect charging system components Check connections at ground cables, p

Page 5 - Quick Diagnostic

Page 5TG0052ASection 4: Advanced TroubleshootingFigure 4 – Alternator-to-Regulator Harness Plug PIN CONNECTIONS Pin A F– Pin

Page 6

Page 6TG0052ASection 4: Advanced TroubleshootingFigure 5 – Alternator-to-Regulator Harness Plug PIN CONNECTIONS Pin A F– Pin

Comments to this Manuals

No comments