TG56B
Table of Contents
Section A: Component Description ..................... 2 – 3
Section B: Basic Troubleshooting .............................4
Section C: Advanced Troubleshooting ................ 5 – 6
NOTICE
Hazard Definitions
These terms are used to bring attention to presence of
hazard(s) of various risk levels or to important information
concerning product life.
Indicates presence of hazard(s) that
will or can cause minor personal
injury or property damage if
ignored.
Indicates special instructions on
installation, operation or mainte-
nance that are important but not
related to personal injury hazards.
CAUTION
NOTICE
Troubleshooting Guide
for N1607 and N1611 Alternators
Battery Conditions
Until temperatures of electrical
system components stabilize, these
conditions may be observed during
cold-start voltage tests.
Maintenance/Low Maintenance Battery
Immediately after engine starts, system volts are
lower than regulator setpoint, amps are medium.
3–5 minutes into charge cycle, system volts
increase, amps decrease.
5–10 minutes into charge cycle, system volts
increase to, or near, regulator setpoint and amps
decrease to a minimum.
Low maintenance battery has same characteristics
with slightly longer recharge times.
Maintenance-free Battery
Immediately after engine starts, system volts are
lower than regulator setpoint, low charging amps.
Once charge cycle begins, low volts and low amps
are still present.
After alternator energizes, voltage will increase
several tenths. Amps will increase gradually, then
quickly, to medium to high amps.
Finally, volts will increase to setpoint and amps will
decrease.
The time it takes to reach optimum voltage and amper-
age will vary with engine speed, load, and ambient
temperature.
High-cycle Maintenance-free Battery
These batteries respond better than standard mainte-
nance-free. Charge acceptance of these batteries may
display characteristics similar to maintenance batteries.
AGM (Absorbed Glass Mat) Maintenance-free Battery
These dry-cell batteries respond better than standard
maintenance-free. If battery state of charge drops to
75% or less, batteries should be recharged to 95% or
higher separately from the engine’s charging system to
avoid damaging charging system components and to
provide best overall performance. Charge acceptance of
these batteries may display
characteristics similar to
maintenance batteries.
Battery Charge Volt and Amp Values
Volt and amp levels fluctuate depending on the battery
state of charge. If batteries are in a state of dischargeas
after extended cranking time to start the engine—system
volts will measure lower than the regulator setpoint after
the
engine is restarted and system amps will measure higher.
This is a normal condition for the charging system; the
greater the battery discharge level, the lower the system
volts and the higher the system amps. The volt and amp
readings will change as batteries recover and become fully
charged: system volts will increase to regulator setpoint
and system amps will decrease to low level (depending on
other loads).
Low Amps: Minimum or lowest charging system amp
value required to maintain battery state of charge,
obtained when testing the charging system with a fully
charged battery and no other loads applied. This value
will vary with battery type.
Medium Amps: System amps value which can cause
the battery temperature to rise above adequate charging
temperature within 4-8 hours of charge time. To prevent
battery damage, the charge amps should be reduced
when battery temperature rises. Check battery manufac-
turer’s recommendations for proper charge amp rates.
High Amps: System amps value which can cause
the battery temperature to rise above adequate charging
temperature within 2-3 hours of charge time. To prevent
battery damage, the charge amps should be reduced
when battery temperature rises. Check battery manufac-
turer’s recommendations for proper charge amp rates.
Battery Voltage: Steady-state voltage value as measured
with battery in open circuit with no battery load. This
value relates to battery state of charge.
Charge Voltage: Voltage value obtained when the
charging system is operating. This value will be higher
than battery voltage and must never exceed the regula-
tor voltage setpoint.
B+ Voltage: Voltage value obtained when measuring
voltage at battery positive terminal or alternator B+
terminal.
Surface Charge: Higher than normal battery voltage
occurring when the battery is disconnected from
battery charger. The surface charge must be removed
to determine true battery voltage and state of charge.
Significant Magnetism: Change in strength or intensity
of a magnetic field present in alternator rotor shaft
when the field coil is energized. The magnetic field
strength when the field coil is energized should feel
stronger than when the field is not energized.
Voltage Droop or Sag: Normal condition occurring
when the load demand on alternator is greater than
rated alternator output at given rotor shaft RPM.
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - Troubleshooting Guide

Page 1TG56BTable of ContentsSection A: Component Description ... 2 – 3 Section B: Basic Troubleshooting ...

Page 2 - CEN N1607 and N1611

Page 2TG56BSection A: Component DescriptionCEN N1607 and N1611 Alternator Description and OperationN1607 500 A 28 V and N1611 570 A 28 V alternators a

Page 3 - (CONT’D)

Page 3TG56BSection A: Component Description (CONT’D)N2013 Battery Isolator Description and OperationN2013 battery isolator used with this charging sy

Page 4

Page 4TG56BSection B: Basic TroubleshootingBasic Troubleshooting1. Inspect charging system components Check connections at ground cables, positiv

Page 5

Page 5TG56BSection C: Advanced TroubleshootingTools and Equipment for Testing• Digital Multimeter (DMM)• Ammeter (digital, inductive) Perform on-ve

Page 6

Page 6TG56BSection C: Advanced Troubleshooting (CONT’D)If you have questions about your alternator or any of these test procedures, or if you need to

Comments to this Manuals