Page 1 of 3
A9-4029 Regulator Wiring Harness Assembly
for C706 Alternators
Replacement Instructions
Figure 1 — Gray Field Connector Attached to
Housing with Clip
This kit contains a new wiring harness with a larger-sized connector assembly than what it
may be replacing. Remove front cover of control unit.
Clip
Wire
tie
Figure 2 — Gray Field Connector Secured with
Wire Ties Only
If gray eld connector
is attached
to the housing with a clip:
If gray eld connector
is secured
with wire ties only:
START ON
PAGE 2
START ON
PAGE 3
These instructions should be used in place of
harness replacement instructions
in 700 Series Service Manual SM7
Page view 0
1 2 3

Summary of Contents

Page 1 - START ON

II169BPage 1 of 3A9-4029 Regulator Wiring Harness Assemblyfor C706 AlternatorsReplacement InstructionsFigure 1 — Gray Field Connector Attached to Hous

Page 2 - Page 2 of 3

II169BPage 2 of 31. Disconnect existing wiring harness terminals: a. Slide existing field connector holder from clip.If the gray fi eld connector is

Page 3 - Page 3 of 3

If the gray fi eld connector is secured with wire ties only...1. Clip wire ties inside control unit.2. Disconnect existing wiring harness terminals:

Comments to this Manuals

No comments