  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Page 1
TG3E
Table of Contents
Section A: Wiring Diagram ........................................... 2
Section B: Basic Troubleshooting ................................. 3
Section C: Advanced Troubleshooting .....................4 – 8
Battery Conditions
Until temperatures of electrical
system components stabilize, these
conditions may be observed during
cold start voltage tests.

Immediately after engine starts, system volts
measure lower than regulator setpoint and
system amps measure at a medium level.
3-5 minutes into charge cycle, volts increase and
amps decrease.
5-10 minutes into charge cycle, volts reach
regulator setpoint or very close, and amps
decrease to a minimum.
Low maintenance battery has same characteris-
tics with slightly longer recharge times.

Immediately after engine starts, system volts
measure lower than regulator setpoint with low
charging amps.
Once the charge cycle begins, low volts and low
amps are still present.
After the alternator energizes, voltage will
increase several tenths. Amps will increase
gradually, then quickly, to medium to high amps.
Finally, volts will increase to setpoint and amps
will decrease.
The time it takes to reach optimum voltage and am-
perage will vary with engine speed, load, and ambient
temperature.

These batteries respond better than standard
maintenance-free. Charge acceptance of these
batteries may display characteristics similar to
maintenance batteries.
NOTICE
Hazard Denitions
These terms are used to bring attention to presence of hazards
of various risk levels or to important information concerning
product life.
Indicates presence of hazard(s) that
will or can cause minor personal
injury or property damage if ignored.
Indicates special instructions on
installation, operation or mainte-
nance that are important but not
related to personal injury hazards.
CAUTION
NOTICE
C701/C701A Alternators
Troubleshooting Guide
Charge Volt and Amp Values
Volt and amp levels fluctuate depending on the battery
state of charge. If batteries are in a state of discharge
as after extended cranking time to start the engine
system volts will measure lower than the regulator set-
point after the engine is restarted and system amps will
measure higher. This is a normal condition for the
charging system; the greater the battery discharge level,
the lower the system volts and the higher the system
amps. The volt and amp readings will change as batter-
ies recover and become fully charged: system volts will
increase to regulator setpoint and system amps will
decrease to low level (depending on other loads).
 Minimum or lowest charging system
amp value required to maintain battery state of
charge, obtained when testing the charging system
with a fully charged battery and no other loads
applied. This value will vary with battery type.
 System amps value which can cause
the battery temperature to rise above adequate
charging temperature within 4-8 hours of charge
time. To prevent battery damage, the charge amps
should be reduced when battery temperature rises.
Check battery manufacturer’s recommendations for
proper charge amp rates.
 System amps value which can cause
the battery temperature to rise above adequate
charging temperature within 2-3 hours of charge
time. To prevent battery damage, the charge amps
should be reduced when battery temperature rises.
Check battery manufacturer’s recommendations for
proper charge amp rates.
 Steady-state voltage value as mea-
sured with battery in open circuit with no battery
load. This value relates to battery state of charge.
 Voltage value obtained when the
charging system is operating. This value will be
higher than battery voltage and must never exceed
the regulator voltage setpoint.
 Voltage value obtained when measuring
voltage at battery positive terminal or alternator B+
terminal.
 Higher than normal battery voltage
occurring when the battery is disconnected from
battery charger. The surface charge must be removed
to determine true battery voltage and state of charge.
 Change in strength or
intensity of a magnetic field present in alternator
rotor shaft when the field coil is energized. The
magnetic field strength when the field coil is ener-
gized should feel stronger than when the field is not
energized.
 Normal condition occurring
when the load demand on alternator is greater than
rated alternator output at given rotor shaft RPM.
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - Troubleshooting Guide

Page 1TG3ETable of ContentsSection A: Wiring Diagram ... 2Section B: Basic Troubleshooting ...

Page 2 - Section A: Wiring Diagram

Page 2TG3ESection A: Wiring DiagramCEN C701/C701A Alternators Description and Operation 28 V, 300 A alternators are internally recti-fied. A

Page 3

Page 3TG3EBasic Troubleshooting1.  Check connections at B– cable, B+ cable, and regulator harness.

Page 4 - Troubleshooting

Page 4TG3ESection C: Advanced TroubleshootingA2-213 RegulatorA2-213 regulator is either attached directly to the out-side of

Page 5 - 

Page 5TG3ESection C: Advanced Troubleshooting (CONT’D)Figure 3 – Alternator-to-Regulator Harness PlugChart 1 – No Alternator Output – 

Page 6 - SOCKET CONNECTIONS

Page 6TG3ESection C: Advanced Troubleshooting(CONT’D)Chart 2 – No Air-Conditioning/Alternator Warning Light OnYesNoConnect DMM red lead to D+ (or P)

Page 7

Page 7TG3ESection C: Advanced Troubleshooting (CONT’D)Test for battery voltage at alternator B+ terminal. Does battery voltage exist?YesNoRepair vehic

Page 8

Page 8TG3ESection C: Advanced Troubleshooting (CONT’D)Repair vehicle circuit to IGN terminal. Vehicle charging circuit test is complete.Set DMM to dio